Item Name | Relay Electromagnetic |
Federal Supply Group (FSG) | Electrical and Electronic Equipment Components |
Federal Supply Class (FSC) | 5945 Relays and Solenoids |
National Item Identification Number (NIIN) | 00-685-8859 (006858859) |
NCB Code | USA (00) |
Manufacturer | Communications Instruments Inc, Allied Signal Inc, Midland Ross Corp, Delivery Systems Inc, Beach Soap Co Inc, American Cyanamid Co, Heico Ohmite Llc, Genicom Corp, Honeywell International Inc, General Electric Company, Interstate Electronics Corporation |
Part Number | Manufacturer | Item Name | Cage Code | RFQ |
---|---|---|---|---|
3SAF5004H1 | communications instruments inc | relay electromagnetic | 1duq5 | RFQ |
1542025-1 | allied signal inc | relay electromagnetic | 83298 | RFQ |
153-1049 | midland ross corp | relay electromagnetic | 04221 | RFQ |
124B125 | delivery systems inc | relay electromagnetic | 55473 | RFQ |
3S2791GC310A21 | beach soap co inc | relay electromagnetic | 91526 | RFQ |
1542025-4 | american cyanamid co | relay electromagnetic | 83289 | RFQ |
1542025-4 | allied signal inc | relay electromagnetic | 83298 | RFQ |
3S2791G310A21 | communications instruments inc | relay electromagnetic | 1duq5 | RFQ |
3S2791G310A21 | heico ohmite llc | relay electromagnetic | 44655 | RFQ |
3S2791G310A21 | genicom corp | relay electromagnetic | 01526 | RFQ |
1542025-4 | honeywell international inc | relay electromagnetic | 64547 | RFQ |
3S2791GC310A21 | general electric company | relay electromagnetic | 24446 | RFQ |
3S2791GC310A21 | genicom corp | relay electromagnetic | 01526 | RFQ |
3SAF5004H1 | genicom corp | relay electromagnetic | 01526 | RFQ |
353-032-001 | interstate electronics corporation | relay electromagnetic | 07421 | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 0.790 INCHES MINIMUM AND 0.800 INCHES MAXIMUM |
ABKW | OVERALL HEIGHT | 0.890 INCHES MINIMUM AND 0.900 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 0.390 INCHES MINIMUM AND 0.400 INCHES MAXIMUM |
ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
AKDX | WINDING QUANTITY | 1 |
AKSL | PURPOSE FOR WHICH DESIGNED | GENERAL |
APCN | COIL QUANTITY | 1 |
APNA | WINDING DC RESISTANCE RATING | 540.0 OHMS MINIMUM SINGLE WINDING AND 660.0 OHMS MAXIMUM SINGLE WINDING |
APNP | DUTY TYPE | CONTINUOUS |
APNQ | ARC QUENCHING METHOD | AIR |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 PLUG-IN TERMINAL SINGLE MOUNTING FACILITY |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CBME | CUBIC MEASURE | 0.281 CUBIC INCHES |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE,DOUBLE THROW,ONE POSITION MOMENTARY |
CRPQ | NOMINAL OPERATING CURRENT RATING AND TYPE | 9.2 MILLIAMPERES DC SINGLE WINDING |
CRXH | TIME DELAY | 0.004 SECONDS MAXIMUM FIXED RELEASE TIME |
CRXH | TIME DELAY | 0.005 SECONDS MAXIMUM FIXED OPERATE TIME |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 26.5 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 1.0 AMPERES AC RESISTIVE LOAD AND 2.0 AMPERES DC RESISTIVE LOAD |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 1.0 AMPERES DC INDUCTIVE LOAD |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
TTQY | TERMINAL TYPE AND QUANTITY | 8 PIN ALL FUNCTIONS |
Relevant Components for NSN - 5945-00-685-8859, 5945006858859 | ||||
5975-01-629-6429 (5975016296429) | 5998-01-305-2341 (5998013052341) | 5930-01-584-0809 (5930015840809) | 5962-01-210-3065 (5962012103065) | |
5905-00-175-4284 (5905001754284) | 5950-01-458-0903 (5950014580903) | 5920-01-490-0904 (5920014900904) | 5998-01-475-9891 (5998014759891) | |
5995-01-575-7529 (5995015757529) | 5962-01-310-7304 (5962013107304) | 5935-01-240-1468 (5935012401468) | 5995-01-374-0247 (5995013740247) | |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote