To receive competitive purchasing options on part number FS-2-3000 by Acme Transformer Co, look no further than NSN Direct. For your reference, this item has the NSN 5950-01-495-0873 and is listed with the description “Transformer Power.” If this matches your needs, we encourage you to fill out the partially-completed quote request form on this page to kick off procurement. By providing comprehensive information about your requirements, such as your desired quantity, pricing, and fulfillment speed, our experts can formulate the most fitting solutions for you. We want to ensure that this process is quick and effortless, so we routinely respond to requests within 15 minutes of receiving and reviewing them.
Note : We Will Not Share Your Information To Any Third Parties.
In addition to our streamlined quotation service, we also aim to make the process of finding products simple. As such, if you require other Acme Transformer Co parts produced under the CAGE Code 83920, you can peruse our manufacturer or CAGE Code catalogs, or use our search engine and filters. Furthermore, if you want to locate items similar to part number FS-2-3000, you can glean from the first four digits of its NSN 5950-01-495-0873 that it belongs to the FSC 5950 Coils and Transformers. This being said, do not hesitate to request quotes on part number FS-2-3000 and any other NSN parts that we feature to experience unrivaled procurement.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-01-495-0873 Item PartTypeName: TRANSFORMER,POWER | 5950 | 014950873 | 0 | P | A | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | A | 0 | |||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
852-00012 | 5 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABTD | MOUNTING SLOT WIDTH | 0.410 INCHES NOMINAL SINGLE GROUP |
ACZB | FREQUENCY RATING | 50.0 HERTZ NOMINAL SINGLE COMPONENT OR 60.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
AGAV | END ITEM IDENTIFICATION | WSD: AIRCRAFT, B-2 BOMBER (ATB) |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AXGY | MOUNTING METHOD | SLOT SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 12.50 AMPERES AC MINIMUM SINGLE COMPONENT SINGLE PRIMARY AND 13.63 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE PRIMARY |
CRBZ | WINDING OPERATING CURRENT | 25.00 AMPERES AC MINIMUM SINGLE COMPONENT SINGLE SECONDARY AND 27.27 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 110.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE SECONDARY AND 115.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE SECONDARY AND 120.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 220.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 230.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 240.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY |
TTQY | TERMINAL TYPE AND QUANTITY | 1 TERMINAL BLOCK W/SCREWS |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.