To receive competitive purchasing options on part number UPL2-27930-1 by Ai Tek Instruments Llc, look no further than NSN Direct. For your reference, this item has the NSN 5925-01-425-1840 and is listed with the description “Circuit Breaker.” If this matches your needs, we encourage you to fill out the partially-completed quote request form on this page to kick off procurement. By providing comprehensive information about your requirements, such as your desired quantity, pricing, and fulfillment speed, our experts can formulate the most fitting solutions for you. We want to ensure that this process is quick and effortless, so we routinely respond to requests within 15 minutes of receiving and reviewing them.
Note : We Will Not Share Your Information To Any Third Parties.
In addition to our streamlined quotation service, we also aim to make the process of finding products simple. As such, if you require other Ai Tek Instruments Llc parts produced under the CAGE Code 1XP56, you can peruse our manufacturer or CAGE Code catalogs, or use our search engine and filters. Furthermore, if you want to locate items similar to part number UPL2-27930-1, you can glean from the first four digits of its NSN 5925-01-425-1840 that it belongs to the FSC 5925 Circuit Breakers. This being said, do not hesitate to request quotes on part number UPL2-27930-1 and any other NSN parts that we feature to experience unrivaled procurement.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-425-1840 Item PartTypeName: CIRCUIT BREAKER | 5925 | 014251840 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
UPL2-27930-1 | 5 | 9 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
CQXF | Inclosure Protection Type For Which Designed | GENERAL PURPOSE |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
CPRJ | Trip Release Method | MAGNETIC ALL LOCATIONS |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 125.0 ALL LOCATIONS |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
AKPX | Pole Quantity | 2 |
CPRX | Actuator Position Designation | AT EACH POLE |
CPSM | Internal Trip Release Configuration | SERIES TRIP W/DUAL RATING ALL LOCATIONS |
FEAT | Special Features | HANDLE COLOR IS BLACK. |
CPLM | Maximum Continuous Load Current Rating Per Pole | 30.0 AMPERES DC ALL LOCATIONS |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 65.0 DC ALL LOCATIONS |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 5000.0 DC ALL LOCATIONS |
MRC | Decoded Requirement | Clear Text Reply |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 0.100 MINIMUM AT 200 PCT ALL LOCATIONS AND 1.700 MAXIMUM AT 200 PCT ALL LOCATIONS |
TTQY | Terminal Type And Quantity | 4 THREADED STUD |
CPRW | Actuator Function | TRIP-RESET |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.