To receive competitive purchasing options on part number 6967ED309A2 by Drs Power And Control Technologies, look no further than NSN Direct. For your reference, this item has the NSN 6110-01-535-7138 and is listed with the description “Controller Motor.” If this matches your needs, we encourage you to fill out the partially-completed quote request form on this page to kick off procurement. By providing comprehensive information about your requirements, such as your desired quantity, pricing, and fulfillment speed, our experts can formulate the most fitting solutions for you. We want to ensure that this process is quick and effortless, so we routinely respond to requests within 15 minutes of receiving and reviewing them.
Note : We Will Not Share Your Information To Any Third Parties.
In addition to our streamlined quotation service, we also aim to make the process of finding products simple. As such, if you require other Drs Power And Control Technologies parts produced under the CAGE Code 27192, you can peruse our manufacturer or CAGE Code catalogs, or use our search engine and filters. Furthermore, if you want to locate items similar to part number 6967ED309A2, you can glean from the first four digits of its NSN 6110-01-535-7138 that it belongs to the FSC 6110 Electrical Control Equipment. This being said, do not hesitate to request quotes on part number 6967ED309A2 and any other NSN parts that we feature to experience unrivaled procurement.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
6110-01-535-7138 Item PartTypeName: CONTROLLER,MOTOR | 6110 | 015357138 | 0 | N | A | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | A | 0 | |||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
6967ED309 | 6 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | Overall Length | 14.100 INCHES NOMINAL |
MRC | Decoded Requirement | Clear Text Reply |
AKPS | Duty Cycle | CONTINUOUS |
CBBL | Features Provided | ACCESSORY LOCATION EXTERNAL AND CIRCUIT PROTECTION FUSE |
AFLW | Actuation Method | MAGNETIC |
ANDG | Fuse Current Rating In Amps | 10 |
ACYN | Ac Voltage Rating | 440.0 VOLTS NOMINAL |
ANCN | Operating Voltage Characteristic | FULL |
ANDW | Load Protection Type | UNDERVOLTAGE AND OVERLOAD |
ANDE | Actuator Voltage | 440.0 AC |
CXCY | Part Name Assigned By Controlling Agency | CONTROLLER A.C. MAGNETIC 2 SPEED 2 WINDING SIZE 1 |
FREQ | Frequency In Hertz | 60 |
ANDX | Ambient Temp | 50.0 DEG CELSIUS |
FEAT | Special Features | SHOCKPROOF GRADE A CLASS 1 OF MIL-S-901;2 SPEED 2 WINDINGS |
FAAZ | Phase | THREE |
ANRK | Switch Functional Positions | SLOW AND FAST AND STOP AND SAFE-RUN |
ABMK | Overall Width | 10.500 INCHES NOMINAL |
ANQC | National Electrical Manufacturers Association Standards Design | DESIGNED PER NEMA STD |
AQZF | Control Type | LOCAL OR REMOTE |
AJXE | Size Designator | 1 |
ABKW | Overall Height | 18.120 INCHES NOMINAL |
ANCY | Horsepower Rating | 10 |
ANPZ | Inclosure Feature | DRIPPROOF |
ACZB | Frequency Rating | 60.0 HERTZ NOMINAL |
ALGC | Mounting Configuration | FOUR 17/32DIA HOLES FORR 1/2DIA MOUNTING BOLTS |
AGUE | Fuse Accommodation Quantity | 3 |
ABFE | Hazardous Locations/Environmental Protection | DRIPPROOF |
AGAV | End Item Identification | MOTOR TERMINALS |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.