To receive competitive purchasing options on part number GF-7563 by Genisco Filter Corp, look no further than NSN Direct. For your reference, this item has the NSN 5915-00-085-0186 and is listed with the description “Filter Radio Frequency Interfere.” If this matches your needs, we encourage you to fill out the partially-completed quote request form on this page to kick off procurement. By providing comprehensive information about your requirements, such as your desired quantity, pricing, and fulfillment speed, our experts can formulate the most fitting solutions for you. We want to ensure that this process is quick and effortless, so we routinely respond to requests within 15 minutes of receiving and reviewing them.
Note : We Will Not Share Your Information To Any Third Parties.
In addition to our streamlined quotation service, we also aim to make the process of finding products simple. As such, if you require other Genisco Filter Corp parts produced under the CAGE Code 07294, you can peruse our manufacturer or CAGE Code catalogs, or use our search engine and filters. Furthermore, if you want to locate items similar to part number GF-7563, you can glean from the first four digits of its NSN 5915-00-085-0186 that it belongs to the FSC 5915 Filters and Networks. This being said, do not hesitate to request quotes on part number GF-7563 and any other NSN parts that we feature to experience unrivaled procurement.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5915-00-085-0186 Item PartTypeName: FILTER,RADIO FREQUENCY INTERFERE | 5915 | 000850186 | P | |||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | ||||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
337-460-9001 | 2 | 2 | 7 |
MRC | Criteria | Characteristic |
---|---|---|
ABKW | OVERALL HEIGHT | 2.130 INCHES MINIMUM AND 2.250 INCHES MAXIMUM |
ADAQ | BODY LENGTH | 2.440 INCHES MINIMUM AND 2.560 INCHES MAXIMUM |
ADAT | BODY WIDTH | 0.720 INCHES MINIMUM AND 0.780 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 1.940 INCHES MINIMUM AND 2.060 INCHES MAXIMUM |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.177 INCHES MINIMUM AND 0.197 INCHES MAXIMUM |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 2.045 INCHES MINIMUM AND 2.075 INCHES MAXIMUM |
AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 1.165 INCHES MINIMUM AND 1.195 INCHES MAXIMUM |
AFGA | OPERATING TEMP RANGE | -65.0 TO 85.0 DEG FAHRENHEIT |
AFSV | AVERAGE LIFE RATING IN HOURS | 250.0 |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 0.5 1ST RADIO INTERFERENCE 1ST FUNCTION |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 0.5 2ND RADIO INTERFERENCE 2ND FUNCTION |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 0.5 3RD RADIO INTERFERENCE 3RD FUNCTION |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 0.5 4TH RADIO INTERFERENCE 4TH FUNCTION |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 150.0 MILLIVOLTS DC 1ST RADIO INTERFERENCE 1ST FUNCTION |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 150.0 MILLIVOLTS DC 2ND RADIO INTERFERENCE 2ND FUNCTION |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 150.0 MILLIVOLTS DC 3RD RADIO INTERFERENCE 3RD FUNCTION |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 150.0 MILLIVOLTS DC 4TH RADIO INTERFERENCE 4TH FUNCTION |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE 1ST FUNCTION |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE 2ND FUNCTION |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE 3RD FUNCTION |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 4TH RADIO INTERFERENCE 4TH FUNCTION |
AKNA | INCLOSURE TYPE | ENCASED |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 CONNECTOR,RECEPTACLE INPUT-OUTPUT/GROUND |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 28.0 VOLTS DC 1ST RADIO INTERFERENCE 1ST FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 28.0 VOLTS DC 2ND RADIO INTERFERENCE 2ND FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 28.0 VOLTS DC 3RD RADIO INTERFERENCE 3RD FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 28.0 VOLTS DC 4TH RADIO INTERFERENCE 4TH FUNCTION |
CRDC | MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE | 200.0 VOLTS AT SEA LEVEL |
FEAT | SPECIAL FEATURES | 1.470 IN. MIN,1.530 IN. MAX O/A WIDTH |
STYL | STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote