To receive competitive purchasing options on part number 42141 by Hydra Electric Company, look no further than NSN Direct. For your reference, this item has the NSN 5930-00-808-1732 and is listed with the description “Switch Pressure.” If this matches your needs, we encourage you to fill out the partially-completed quote request form on this page to kick off procurement. By providing comprehensive information about your requirements, such as your desired quantity, pricing, and fulfillment speed, our experts can formulate the most fitting solutions for you. We want to ensure that this process is quick and effortless, so we routinely respond to requests within 15 minutes of receiving and reviewing them.
Note : We Will Not Share Your Information To Any Third Parties.
In addition to our streamlined quotation service, we also aim to make the process of finding products simple. As such, if you require other Hydra Electric Company parts produced under the CAGE Code 98505, you can peruse our manufacturer or CAGE Code catalogs, or use our search engine and filters. Furthermore, if you want to locate items similar to part number 42141, you can glean from the first four digits of its NSN 5930-00-808-1732 that it belongs to the FSC 5930 Switches. This being said, do not hesitate to request quotes on part number 42141 and any other NSN parts that we feature to experience unrivaled procurement.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5930-00-808-1732 Item PartTypeName: SWITCH,PRESSURE | 5930 | 008081732 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
42141 | 6 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 2.938 INCHES MAXIMUM |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.203 INCHES NOMINAL |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 3.000 INCHES NOMINAL |
AJZC | PRESSURE SWITCH TYPE | GAGE |
CQJB | PROOF PRESSURE | 120.00 POUNDS PER SQUARE INCH |
CQJX | NOMINAL THREAD SIZE | 0.438 INCHES SINGLE PRESSURE CONNECTION |
CQYJ | MOUNTING FACILITY PATTERN | TWO POSITION IN-LINE |
CSCC | SENSING ELEMENT BURST PRESSURE | 180.00 POUNDS PER SQUARE INCH |
CTYC | CONTACT ADJUSTABILITY | DEACTUATION POINT ADJUSTABLE,PRESET AND ACTUATION POINT ADJUSTABLE,PRESET |
CTYM | CONTACT ADJUSTMENT RANGE | 3.00/60.00 ACTUATION POINT POUNDS PER SQUARE INCH AND 3.00 TO 60.00 DEACTUATION POINT POUNDS PER SQUARE INCH |
CTYS | CONTACT ADJUSTMENT TYPE | INTERNAL DEACTUATION POINT SCREW AND INTERNAL ACTUATION POINT SCREW |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 28.0 DC AT SEA LEVEL SINGLE VOLTAGE |
CTZL | PRESSURE CONNECTOR TYPE | PLAIN,THREADED INTERNAL SINGLE CONNECTION |
THSD | THREAD SERIES DESIGNATOR | UNF SINGLE PRESSURE CONNECTION |
AAJD | THREAD CLASS | 3B SINGLE PRESSURE CONNECTION |
ABKW | OVERALL HEIGHT | 3.125 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 3.625 INCHES NOMINAL |
AWTN | OPERATING TEMP RATING | -65.0 DEG FAHRENHEIT MINIMUM AND 160.0 DEG FAHRENHEIT MAXIMUM |
AXGY | MOUNTING METHOD | BRACKET AND UNTHREADED HOLE |
CBBL | FEATURES PROVIDED | ELECTRICAL BOX CONNECTOR |
CMLP | THREAD QUANTITY PER INCH | 20 SINGLE PRESSURE CONNECTION |
CQGB | CONTACT ACTION STIMULUS | INCREASE |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE,DOUBLE THROW,ONE POSITION MOMENTARY |
CSCF | TERMINAL TYPE | CONNECTOR,RECEPTACLE |
CTHF | CONTACT LOAD CURRENT RATING | 3.0 AMPERES RESISTIVE LOAD SINGLE VOLTAGE |
CTYX | CONTACT STIMULUS RATING | 15.00 ACTUATION POINT NOMINAL POUNDS PER SQUARE INCH AND 13.00 DEACTUATION POINT NOMINAL POUNDS PER SQUARE INCH AND 2.00 DIFFERENTIAL POINT NOMINAL POUNDS PER SQUARE INCH |
MEDA | MEDIA FOR WHICH DESIGNED | GAS OR LIQUID |
STYL | STYLE DESIGNATOR | CYLINDRICAL W/MOUNTING LUGS |