To receive competitive purchasing options on part number 29400 by Janke And Company Inc, look no further than NSN Direct. For your reference, this item has the NSN 4920-01-062-1938 and is listed with the description “Test Stand Hydrauli.” If this matches your needs, we encourage you to fill out the partially-completed quote request form on this page to kick off procurement. By providing comprehensive information about your requirements, such as your desired quantity, pricing, and fulfillment speed, our experts can formulate the most fitting solutions for you. We want to ensure that this process is quick and effortless, so we routinely respond to requests within 15 minutes of receiving and reviewing them.
Note : We Will Not Share Your Information To Any Third Parties.
In addition to our streamlined quotation service, we also aim to make the process of finding products simple. As such, if you require other Janke And Company Inc parts produced under the CAGE Code 31682, you can peruse our manufacturer or CAGE Code catalogs, or use our search engine and filters. Furthermore, if you want to locate items similar to part number 29400, you can glean from the first four digits of its NSN 4920-01-062-1938 that it belongs to the FSC 4920 Aircraft Maintenance And Repair Shop Specialized Equipment. This being said, do not hesitate to request quotes on part number 29400 and any other NSN parts that we feature to experience unrivaled procurement.
MRC | Criteria | Characteristic |
---|---|---|
CHGQ | FILTERING SYSTEM | INCLUDED |
CHGR | PRESSURE/SUCTION HOSE | INCLUDED |
CGYK | ENGINE DRIVEN HYDRAULIC PUMP TESTING DESIGN FEATURE | NOT INCLUDED |
CGYM | PRESSURE MANIFOLD SUBCIRCUIT | NOT INCLUDED |
ATJK | POWER SOURCE | GASOLINE ENGINE |
FTLD | III FUNCTIONAL DESCRIPTION | DETERMINES PERFORMANCE AND OPERATING CHARACTERISTICS OF AIRCRAFT HYDRAULIC SYSTEM TESTING FOR EXTERNAL AND INTERNAL LEAKAGES AND DRAINS, FLUSHES AND REFILLS SYSTEM WITH MICRONICALLY-FILTERED FLUID |
AYJM | ACCUMULATOR | INCLUDED |
AKYN | FURNISHED ITEMS AND QUANTITY | TONGUE PULLING 1 |
BGST | PRESSURE RATING | 3000.0 POUNDS PER SQUARE INCH MINIMUM AND 5000.0 POUNDS PER SQUARE INCH MAXIMUM |
AAYJ | HYDRAULIC FLUID FLOW RATE | 30.0 GALLONS PER MINUTE |
RDAL | III REFERENCE DATA AND LITERATURE | T.O.33A2-2-21-34 |
ALBY | USAGE DESIGN | AIRCRAFT HYDRAULIC SYSTEM |
FEAT | SPECIAL FEATURES | SINGLE SYSTEM, THE TEST STAND ALSO HAS A REDUCED HYDRAULIC FLOW OF 15GPM AT 5000 PSI |
AMQY | INSTALLATION DESIGN | PORTABLE |