To receive competitive purchasing options on part number 950-0282-000 by L 3 Communications Corporation, look no further than NSN Direct. For your reference, this item has the NSN 5950-00-880-6005 and is listed with the description “Transformer Power Autotransforme.” If this matches your needs, we encourage you to fill out the partially-completed quote request form on this page to kick off procurement. By providing comprehensive information about your requirements, such as your desired quantity, pricing, and fulfillment speed, our experts can formulate the most fitting solutions for you. We want to ensure that this process is quick and effortless, so we routinely respond to requests within 15 minutes of receiving and reviewing them.
Note : We Will Not Share Your Information To Any Third Parties.
In addition to our streamlined quotation service, we also aim to make the process of finding products simple. As such, if you require other L 3 Communications Corporation parts produced under the CAGE Code 27777, you can peruse our manufacturer or CAGE Code catalogs, or use our search engine and filters. Furthermore, if you want to locate items similar to part number 950-0282-000, you can glean from the first four digits of its NSN 5950-00-880-6005 that it belongs to the FSC 5950 Coils and Transformers. This being said, do not hesitate to request quotes on part number 950-0282-000 and any other NSN parts that we feature to experience unrivaled procurement.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-880-6005 Item PartTypeName: TRANSFORMER,POWER AUTOTRANSFORME | 5950 | 008806005 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
950-0282-000 | C | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 6.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABTB | MOUNTING HOLE DIAMETER | 0.297 INCHES NOMINAL SINGLE GROUP |
ACZD | TRANSFORMER WINDING CONNECTION TYPE | OPEN DELTA-WYE |
ADAU | BODY HEIGHT | 5.125 INCHES NOMINAL |
AEHZ | MAXIMUM OPERATING TEMP | 72.0 DEG CELSIUS |
AKNA | INCLOSURE TYPE | OPEN |
AXGY | MOUNTING METHOD | UNTHREADED HOLE SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY,FIXED AUTOTRANSFORMER TYPE SINGLE COMPONENT |
CRMJ | WINDING POWER RATING | 6.0 KILOVOLT-AMPERES SINGLE COMPONENT SINGLE PRIMARY INPUT |
CWJS | WINDING OPERATING VOLTAGE | 200.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL PRIMARY |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO THREE PHASE SINGLE COMPONENT |
ADAQ | BODY LENGTH | 6.750 INCHES NOMINAL |
ADAT | BODY WIDTH | 4.750 INCHES NOMINAL |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 12.8 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE PRIMARY OUTPUT |
CWJS | WINDING OPERATING VOLTAGE | 300.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL SECONDARY AND 470.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL SECONDARY |
TTQY | TERMINAL TYPE AND QUANTITY | 21 WIRE LEAD |