To receive competitive purchasing options on part number 587R294H15 by Microtech Ltd, look no further than NSN Direct. For your reference, this item has the NSN 5985-01-334-1108 and is listed with the description “Waveguideassembly.” If this matches your needs, we encourage you to fill out the partially-completed quote request form on this page to kick off procurement. By providing comprehensive information about your requirements, such as your desired quantity, pricing, and fulfillment speed, our experts can formulate the most fitting solutions for you. We want to ensure that this process is quick and effortless, so we routinely respond to requests within 15 minutes of receiving and reviewing them.
Note : We Will Not Share Your Information To Any Third Parties.
In addition to our streamlined quotation service, we also aim to make the process of finding products simple. As such, if you require other Microtech Ltd parts produced under the CAGE Code 54647, you can peruse our manufacturer or CAGE Code catalogs, or use our search engine and filters. Furthermore, if you want to locate items similar to part number 587R294H15, you can glean from the first four digits of its NSN 5985-01-334-1108 that it belongs to the FSC 5985 Antennas Waveguides and Related Equipment. This being said, do not hesitate to request quotes on part number 587R294H15 and any other NSN parts that we feature to experience unrivaled procurement.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5985-01-334-1108 Item PartTypeName: WAVEGUIDE ASSEMBLY | 5985 | 013341108 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
7 | S | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
587R294H15 | 6 | 2 | 1 |
MRC | Criteria | Characteristic |
---|---|---|
AHRV | TUBING WALL CONSTRUCTION STYLE | SEAMLESS FIFTH TUBING SEGMENT |
CQHN | WAVEGUIDE OUTSIDE WIDTH | 0.996 INCHES MINIMUM AND 1.004 INCHES MAXIMUM |
SFTT | SURFACE TREATMENT | ENAMEL ALL TUBING SEGMENT AND FLANGE OUTSIDE SURFACES AND PASSIVATE ALL TUBING SEGMENT AND FLANGE OUTSIDE SURFACES AND PRIMER ALL TUBING SEGMENT AND FLANGE OUTSIDE SURFACES |
AAGR | CROSS-SECTIONAL SHAPE STYLE | INTERNAL,RECTANGULAR EXTERNAL,RECTANGULAR |
AAJD | THREAD CLASS | 2B ALL FLANGES ALL CONNECTION FACILITIES |
AGAV | END ITEM IDENTIFICATION | F-16 |
AHRV | TUBING WALL CONSTRUCTION STYLE | SEAMLESS THIRD TUBING SEGMENT |
AHSX | FLANGE INSIDE WIDTH | 0.896 INCHES MINIMUM ALL FLANGES AND 0.904 INCHES MAXIMUM ALL FLANGES |
AHTD | FLANGE DEPTH | 0.423 INCHES MINIMUM ALL FLANGES AND 0.453 INCHES MAXIMUM ALL FLANGES |
CQJX | NOMINAL THREAD SIZE | 0.164 INCHES ALL FLANGES ALL CONNECTION FACILITIES |
CRLB | WAVEGUIDE INSIDE HEIGHT | 0.396 INCHES MINIMUM AND 0.404 INCHES MAXIMUM |
CSFC | WAVEGUIDE OUTSIDE HEIGHT | 0.496 INCHES MINIMUM AND 0.504 INCHES MAXIMUM |
FLEX | FLEXIBILITY | RIGID FOURTH TUBING SEGMENT |
MATT | MATERIAL | ALUMINUM ALLOY ALL TUBING SEGMENT AND FLANGE |
SFTT | SURFACE TREATMENT | SILVER ALL TUBING SEGMENT INSIDE SURFACES |
ZZZV | FSC APPLICATION DATA | ANTENNAS,WAVEGUIDES,AND RELATED EQUIP. |
AAJF | THREAD DIRECTION | RIGHT-HAND ALL FLANGES ALL CONNECTION FACILITIES |
AHRV | TUBING WALL CONSTRUCTION STYLE | CORRUGATED SECOND TUBING SEGMENT |
AHRV | TUBING WALL CONSTRUCTION STYLE | SEAMLESS FOURTH TUBING SEGMENT |
AHRW | TUBING TWIST TYPE | STRAIGHT TWIST SECOND TUBING SEGMENT |
AHRX | TUBING TWIST ANGLE IN DEG | 90.0 SECOND TUBING SEGMENT |
AHSF | FLANGE QUANTITY | 2 |
AHTW | VOLTAGE STANDING WAVE RATIO | 1.35 |
CRFH | WAVEGUIDE INSIDE WIDTH | 0.896 INCHES MINIMUM AND 0.904 INCHES MAXIMUM |
CTCJ | FLANGE STYLE | CHOKE TYPE ALL FLANGES |
FLEX | FLEXIBILITY | FLEXIBLE SECOND TUBING SEGMENT |
FLEX | FLEXIBILITY | RIGID FIFTH TUBING SEGMENT |
FLEX | FLEXIBILITY | RIGID FIRST TUBING SEGMENT |
FLEX | FLEXIBILITY | RIGID SIXTH TUBING SEGMENT |
FLEX | FLEXIBILITY | RIGID THIRD TUBING SEGMENT |
PMLC | PRECIOUS MATERIAL AND LOCATION | INTERNAL SURFACES SILVER |
PRMT | PRECIOUS MATERIAL | SILVER |
THSD | THREAD SERIES DESIGNATOR | UNC ALL FLANGES ALL CONNECTION FACILITIES |
AHRV | TUBING WALL CONSTRUCTION STYLE | SEAMLESS FIRST TUBING SEGMENT |
AHRV | TUBING WALL CONSTRUCTION STYLE | SEAMLESS SIXTH TUBING SEGMENT |
AHSY | FLANGE INSIDE HEIGHT | 0.396 INCHES MINIMUM ALL FLANGES AND 0.404 INCHES MAXIMUM ALL FLANGES |
AHSZ | FLANGE OUTSIDE WIDTH | 1.610 INCHES MINIMUM ALL FLANGES AND 1.640 INCHES MAXIMUM ALL FLANGES |
AHTA | FLANGE OUTSIDE HEIGHT | 1.610 INCHES MINIMUM ALL FLANGES AND 1.640 INCHES MAXIMUM ALL FLANGES |
AHTX | INSERTION LOSS IN DECIBELS | 0.25 |
CSQT | FLANGE CONNECTING FACILITY AND QUANTITY | 4 THREADED HOLE ALL FLANGES ALL CONNECTION FACILITIES |
FEAT | SPECIAL FEATURES | FLANGES HAVE RESONANCE SUPPRESSOR AND CAPTURED SCREWS INCLUDED WITH EACH FLANGE |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.