To receive competitive purchasing options on part number 2868625-1 by Navair And Navsea Managed, look no further than NSN Direct. For your reference, this item has the NSN 5905-00-405-2433 and is listed with the description “Resistor Network Fixed Wirewound.” If this matches your needs, we encourage you to fill out the partially-completed quote request form on this page to kick off procurement. By providing comprehensive information about your requirements, such as your desired quantity, pricing, and fulfillment speed, our experts can formulate the most fitting solutions for you. We want to ensure that this process is quick and effortless, so we routinely respond to requests within 15 minutes of receiving and reviewing them.
Note : We Will Not Share Your Information To Any Third Parties.
In addition to our streamlined quotation service, we also aim to make the process of finding products simple. As such, if you require other Navair And Navsea Managed parts produced under the CAGE Code 10001, you can peruse our manufacturer or CAGE Code catalogs, or use our search engine and filters. Furthermore, if you want to locate items similar to part number 2868625-1, you can glean from the first four digits of its NSN 5905-00-405-2433 that it belongs to the FSC 5905 Resistors. This being said, do not hesitate to request quotes on part number 2868625-1 and any other NSN parts that we feature to experience unrivaled procurement.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5905-00-405-2433 Item PartTypeName: RESISTOR NETWORK,FIXED,WIRE WOUN | 5905 | 004052433 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
183146 | 2 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AAPE | TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS | -260.0/260.0 |
AAPP | ELECTRICAL RESISTANCE | 101.716 KILOHMS |
AAPP | ELECTRICAL RESISTANCE | 119.985 KILOHMS 10TH INTERMEDIATE RESISTANCE VALUE |
AAPP | ELECTRICAL RESISTANCE | 13.506 KILOHMS LOWEST RESISTANCE VALUE |
AAPP | ELECTRICAL RESISTANCE | 139.985 KILOHMS 11TH INTERMEDIATE RESISTANCE VALUE |
AAPP | ELECTRICAL RESISTANCE | 14.063 KILOHMS |
AAPP | ELECTRICAL RESISTANCE | 159.985 KILOHMS 12TH INTERMEDIATE RESISTANCE VALUE |
AAPP | ELECTRICAL RESISTANCE | 179.985 KILOHMS 13TH INTERMEDIATE RESISTANCE VALUE |
AAPP | ELECTRICAL RESISTANCE | 180.000 KILOHMS 14TH INTERMEDIATE RESISTANCE VALUE |
AAPP | ELECTRICAL RESISTANCE | 225.704 KILOHMS HIGHEST RESISTANCE VALUE |
AAPP | ELECTRICAL RESISTANCE | 26.013 KILOHMS 2ND INTERMEDIATE RESISTANCE VALUE |
AAPP | ELECTRICAL RESISTANCE | 28.156 KILOHMS |
AAPP | ELECTRICAL RESISTANCE | 39.985 KILOHMS 4TH INTERMEDIATE RESISTANCE VALUE |
AAPP | ELECTRICAL RESISTANCE | 59.985 KILOHMS 5TH INTERMEDIATE RESISTANCE VALUE |
AAPP | ELECTRICAL RESISTANCE | 79.985 KILOHMS |
AAPP | ELECTRICAL RESISTANCE | 80.000 KILOHMS 7TH INTERMEDIATE RESISTANCE VALUE |
AAPP | ELECTRICAL RESISTANCE | 99.985 KILOHMS |
AAPQ | RESISTANCE TOLERANCE IN PERCENT | -5.000/5.000 |
AAQF | AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER | 125.0 |
AAQG | AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER | 145.0 |
AAQH | TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS | -65.0/145.0 |
AAQZ | INCLOSURE METHOD | ENCAPSULATED |
AARA | TERMINAL QUANTITY | 20 |
AARB | TERMINAL TYPE | PIN |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABJT | TERMINAL LENGTH | 0.135 INCHES MINIMUM |
ADAQ | BODY LENGTH | 3.000 INCHES NOMINAL |
ADAT | BODY WIDTH | 1.000 INCHES NOMINAL |
ADAU | BODY HEIGHT | 0.650 INCHES MAXIMUM |
AEFB | POWER DISSIPATION RATING IN WATTS | 0.500 TOTAL NETWORK |
CBME | CUBIC MEASURE | 1.950 CUBIC INCHES |
CQRD | IDENTICAL VALUE RESISTOR QUANTITY | 1 10TH INTERMEDIATE RESISTANCE VALUE |
CQRD | IDENTICAL VALUE RESISTOR QUANTITY | 1 11TH INTERMEDIATE RESISTANCE VALUE |
CQRD | IDENTICAL VALUE RESISTOR QUANTITY | 1 12TH INTERMEDIATE RESISTANCE VALUE |
CQRD | IDENTICAL VALUE RESISTOR QUANTITY | 1 13TH INTERMEDIATE RESISTANCE VALUE |
CQRD | IDENTICAL VALUE RESISTOR QUANTITY | 1 14TH INTERMEDIATE RESISTANCE VALUE |
CQRD | IDENTICAL VALUE RESISTOR QUANTITY | 1 1ST INTERMEDIATE RESISTANCE VALUE |
CQRD | IDENTICAL VALUE RESISTOR QUANTITY | 1 2ND INTERMEDIATE RESISTANCE VALUE |
CQRD | IDENTICAL VALUE RESISTOR QUANTITY | 1 3RD INTERMEDIATE RESISTANCE VALUE |
CQRD | IDENTICAL VALUE RESISTOR QUANTITY | 1 4TH INTERMEDIATE RESISTANCE VALUE |
CQRD | IDENTICAL VALUE RESISTOR QUANTITY | 1 5TH INTERMEDIATE RESISTANCE VALUE |
CQRD | IDENTICAL VALUE RESISTOR QUANTITY | 1 6TH INTERMEDIATE RESISTANCE VALUE |
CQRD | IDENTICAL VALUE RESISTOR QUANTITY | 1 8TH INTERMEDIATE RESISTANCE VALUE |
CQRD | IDENTICAL VALUE RESISTOR QUANTITY | 1 9TH INTERMEDIATE RESISTANCE VALUE |
CQRD | IDENTICAL VALUE RESISTOR QUANTITY | 1 HIGHEST RESISTANCE VALUE |
CQRD | IDENTICAL VALUE RESISTOR QUANTITY | 1 LOWEST RESISTANCE VALUE |
CQRD | IDENTICAL VALUE RESISTOR QUANTITY | 2 7TH INTERMEDIATE RESISTANCE VALUE |
FEAT | SPECIAL FEATURES | NON-INDUCTIVE |
STYL | STYLE DESIGNATOR | DUAL INLINE |
TEST | TEST DATA DOCUMENT | 10001-2868625 DRAWING (THIS IS THE BASIC GOVERNING DRAWING,SUCH AS A CONTRACTOR DRAWING,ORIGINAL EQUIPMENT MANUFACTURER DRAWING,ETC.; EXCLUDES ANY SPECIFICATION,STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAW |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.