To receive competitive purchasing options on part number FXD63B125 by Siemens Energy And Automation Inc, look no further than NSN Direct. For your reference, this item has the NSN 5925-01-479-4493 and is listed with the description “Circuit Breaker.” If this matches your needs, we encourage you to fill out the partially-completed quote request form on this page to kick off procurement. By providing comprehensive information about your requirements, such as your desired quantity, pricing, and fulfillment speed, our experts can formulate the most fitting solutions for you. We want to ensure that this process is quick and effortless, so we routinely respond to requests within 15 minutes of receiving and reviewing them.
Note : We Will Not Share Your Information To Any Third Parties.
In addition to our streamlined quotation service, we also aim to make the process of finding products simple. As such, if you require other Siemens Energy And Automation Inc parts produced under the CAGE Code 66842, you can peruse our manufacturer or CAGE Code catalogs, or use our search engine and filters. Furthermore, if you want to locate items similar to part number FXD63B125, you can glean from the first four digits of its NSN 5925-01-479-4493 that it belongs to the FSC 5925 Circuit Breakers. This being said, do not hesitate to request quotes on part number FXD63B125 and any other NSN parts that we feature to experience unrivaled procurement.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-479-4493 Item PartTypeName: CIRCUIT BREAKER | 5925 | 014794493 | P | A | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
A | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
FXD63B125 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
CSSX | Switch Current Rating And Type In Amps | 250.0 AC |
MRC | Decoded Requirement | Clear Text Reply |
CPLM | Maximum Continuous Load Current Rating Per Pole | 125.0 AMPERES AC ALL LOCATIONS |
AKPX | Pole Quantity | 3 |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 600.0 AC ALL LOCATIONS |
FREQ | Frequency In Hertz | 50.0 ALL LOCATIONS OR 60.0 ALL LOCATIONS |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
ABMK | Overall Width | 4.500 INCHES NOMINAL |
CPRJ | Trip Release Method | THERMAL-MAGNETIC ALL LOCATIONS |
CPRL | Trip Release Characteristic | INSTANTANEOUS ALL LOCATIONS |
CRCF | Trip Release Ambient Temp Rating | 40.0 DEG CELSIUS NOMINAL ALL LOCATIONS |
ADTV | Case Material | PLASTIC |
CSWP | Switch Voltage Rating And Type In Volts | 600.0 AC |
CXCY | Part Name Assigned By Controlling Agency | FD 250A FRAME SENTRON SERIES, THERMAL-MAGNETIC TRIP BREAKERS |
ABHP | Overall Length | 9.500 INCHES NOMINAL |
AAQL | Body Style | |
ABKW | Overall Height | 4.000 INCHES NOMINAL |
FEAT | Special Features | NON-INTERCHANGEABLE TRIP (ASSEMBLED CIRCUIT BREAKER - WITHOUT LUGS) |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 18000.0 AC ALL LOCATIONS |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote