To receive competitive purchasing options on part number TP892 by Sora Power Inc, look no further than NSN Direct. For your reference, this item has the NSN 5950-01-136-1946 and is listed with the description “Transformerpulse.” If this matches your needs, we encourage you to fill out the partially-completed quote request form on this page to kick off procurement. By providing comprehensive information about your requirements, such as your desired quantity, pricing, and fulfillment speed, our experts can formulate the most fitting solutions for you. We want to ensure that this process is quick and effortless, so we routinely respond to requests within 15 minutes of receiving and reviewing them.
Note : We Will Not Share Your Information To Any Third Parties.
In addition to our streamlined quotation service, we also aim to make the process of finding products simple. As such, if you require other Sora Power Inc parts produced under the CAGE Code 13058, you can peruse our manufacturer or CAGE Code catalogs, or use our search engine and filters. Furthermore, if you want to locate items similar to part number TP892, you can glean from the first four digits of its NSN 5950-01-136-1946 that it belongs to the FSC 5950 Coils and Transformers. This being said, do not hesitate to request quotes on part number TP892 and any other NSN parts that we feature to experience unrivaled procurement.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-01-136-1946 Item PartTypeName: TRANSFORMER,PULSE | 5950 | 011361946 | 0 | Y | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
142471-1 | 2 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 10.740 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 10.760 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 7.970 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 8.030 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABTB | MOUNTING HOLE DIAMETER | 0.250 INCHES NOMINAL SINGLE GROUP |
ACZH | PRIMARY TO SECONDARY TURN RATIO | 1 TO 9-1/4 SINGLE COMPONENT |
ACZN | PULSE REPETITION RATE | 6.0 KILOHERTZ SINGLE COMPONENT |
ACZX | WINDING SHIELDING METHOD | CORE GROUNDED TO INCLOSURE SINGLE COMPONENT |
ADAQ | BODY LENGTH | 11.720 INCHES MINIMUM AND 11.780 INCHES MAXIMUM |
ADAT | BODY WIDTH | 8.970 INCHES MINIMUM AND 9.030 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 5.970 INCHES MINIMUM AND 6.030 INCHES MAXIMUM |
AEHZ | MAXIMUM OPERATING TEMP | 130.0 DEG CELSIUS |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
AKPV | MOUNTING FACILITY QUANTITY | 6 SINGLE GROUP |
AXGY | MOUNTING METHOD | UNTHREADED HOLE SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 6.8 AMPERES DC MAXIMUM SINGLE COMPONENT SINGLE PRIMARY |
CRGS | DC RESISTANCE RATING IN OHMS | 0.800 SINGLE COMPONENT 1ST SECONDARY |
TTQY | TERMINAL TYPE AND QUANTITY | 6 STANDOFF,THREADED STUD |