To receive competitive purchasing options on part number 11147 by Sora Power Inc, look no further than NSN Direct. For your reference, this item has the NSN 5950-01-181-1754 and is listed with the description “Transformer Power Autotransforme.” If this matches your needs, we encourage you to fill out the partially-completed quote request form on this page to kick off procurement. By providing comprehensive information about your requirements, such as your desired quantity, pricing, and fulfillment speed, our experts can formulate the most fitting solutions for you. We want to ensure that this process is quick and effortless, so we routinely respond to requests within 15 minutes of receiving and reviewing them.
Note : We Will Not Share Your Information To Any Third Parties.
In addition to our streamlined quotation service, we also aim to make the process of finding products simple. As such, if you require other Sora Power Inc parts produced under the CAGE Code 55196, you can peruse our manufacturer or CAGE Code catalogs, or use our search engine and filters. Furthermore, if you want to locate items similar to part number 11147, you can glean from the first four digits of its NSN 5950-01-181-1754 that it belongs to the FSC 5950 Coils and Transformers. This being said, do not hesitate to request quotes on part number 11147 and any other NSN parts that we feature to experience unrivaled procurement.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-01-181-1754 Item PartTypeName: TRANSFORMER,POWER AUTOTRANSFORME | 5950 | 011811754 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
865406-0001 | 6 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AKPV | MOUNTING FACILITY QUANTITY | 2 SINGLE GROUP |
AXGY | MOUNTING METHOD | THREADED HOLE SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY,FIXED AUTOTRANSFORMER TYPE SINGLE COMPONENT |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 16.0 AMPERES DC NOMINAL SINGLE COMPONENT SINGLE PRIMARY OUTPUT |
CWJS | WINDING OPERATING VOLTAGE | 13.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY OUTPUT |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 4 SOLDER STUD |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABHP | OVERALL LENGTH | 1.870 INCHES MINIMUM AND 1.930 INCHES MAXIMUM |
ABKW | OVERALL HEIGHT | 1.600 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 1.130 INCHES MAXIMUM |
ACZB | FREQUENCY RATING | 25.0 KILOHERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
AEHZ | MAXIMUM OPERATING TEMP | 155.0 DEG CELSIUS |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 1.490 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.510 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |