To receive competitive purchasing options on part number 462A023-5 by Tyco Electronics Corporation, look no further than NSN Direct. For your reference, this item has the NSN 5970-00-968-0565 and is listed with the description “Insulation Sleeving Electrical S.” If this matches your needs, we encourage you to fill out the partially-completed quote request form on this page to kick off procurement. By providing comprehensive information about your requirements, such as your desired quantity, pricing, and fulfillment speed, our experts can formulate the most fitting solutions for you. We want to ensure that this process is quick and effortless, so we routinely respond to requests within 15 minutes of receiving and reviewing them.
Note : We Will Not Share Your Information To Any Third Parties.
In addition to our streamlined quotation service, we also aim to make the process of finding products simple. As such, if you require other Tyco Electronics Corporation parts produced under the CAGE Code 06090, you can peruse our manufacturer or CAGE Code catalogs, or use our search engine and filters. Furthermore, if you want to locate items similar to part number 462A023-5, you can glean from the first four digits of its NSN 5970-00-968-0565 that it belongs to the FSC 5970 Electrical Insulators and Insulating Materials. This being said, do not hesitate to request quotes on part number 462A023-5 and any other NSN parts that we feature to experience unrivaled procurement.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5970-00-968-0565 Item PartTypeName: INSULATION SLEEVING,ELECTRICAL,S | 5970 | 009680565 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
462A023-5 | 5 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AAPB | DIELECTRIC WITHSTANDING VOLTAGE IN VOLTS | 10000.0 |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABJH | TEMP RATING | -55.0 DEG CELSIUS AND 80.0 DEG CELSIUS |
AFZU | MAIN BODY INSIDE DIAMETER | 0.490 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
AFZU | MAIN BODY INSIDE DIAMETER | 1.060 INCHES MINIMUM AS SUPPLIED |
AFZV | FIRST BRANCH INSIDE DIAMETER | 0.240 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
AFZV | FIRST BRANCH INSIDE DIAMETER | 0.520 INCHES MINIMUM AS SUPPLIED |
AFZW | SECOND BRANCH INSIDE DIAMETER | 0.240 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
AFZW | SECOND BRANCH INSIDE DIAMETER | 0.520 INCHES MINIMUM AS SUPPLIED |
AFZX | THIRD BRANCH INSIDE DIAMETER | 0.240 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
AFZX | THIRD BRANCH INSIDE DIAMETER | 0.520 INCHES MINIMUM AS SUPPLIED |
AGAA | DISTANCE FROM INTERSECTING CENTERLINE OF MAIN BODY TO END OF FIRST BRANCH | 1.780 INCHES MINIMUM AND 2.180 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
AGAA | DISTANCE FROM INTERSECTING CENTERLINE OF MAIN BODY TO END OF FIRST BRANCH | 1.980 INCHES MAXIMUM AS SUPPLIED |
AGAB | MAIN BODY WALL THICKNESS | 0.080 INCHES MINIMUM AND 0.120 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
AGAB | MAIN BODY WALL THICKNESS | 0.100 INCHES MAXIMUM AS SUPPLIED |
AGAC | FIRST BRANCH WALL THICKNESS | 0.050 INCHES MINIMUM AND 0.070 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
AGAC | FIRST BRANCH WALL THICKNESS | 0.060 INCHES MAXIMUM AS SUPPLIED |
AGAD | SECOND BRANCH WALL THICKNESS | 0.050 INCHES MINIMUM AND 0.070 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
AGAD | SECOND BRANCH WALL THICKNESS | 0.060 INCHES MAXIMUM AS SUPPLIED |
AGAE | THIRD BRANCH WALL THICKNESS | 0.050 INCHES MINIMUM AND 0.070 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
AGAE | THIRD BRANCH WALL THICKNESS | 0.060 INCHES MAXIMUM AS SUPPLIED |
AGAG | DISTANCE FROM EDGE OF MAIN BODY TO INTERSECTING CENTERLINES | 1.520 INCHES MINIMUM AND 1.860 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
AGAG | DISTANCE FROM EDGE OF MAIN BODY TO INTERSECTING CENTERLINES | 1.690 INCHES MAXIMUM AS SUPPLIED |
AGAH | MAIN BODY OVERALL LENGTH | 3.300 INCHES MINIMUM AND 4.040 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
AGAH | MAIN BODY OVERALL LENGTH | 4.040 INCHES MAXIMUM AS SUPPLIED |
AGAQ | ANGLE BETWEEN MAIN BODY AND FIRST BRANCH CENTERLINES IN DEG | 20.0 MAXIMUM AS SUPPLIED |
AGAQ | ANGLE BETWEEN MAIN BODY AND FIRST BRANCH CENTERLINES IN DEG | 25.0 MINIMUM AND 35.0 MAXIMUM AFTER UNRESTRICTED RECOVERY |
CQBC | MINIMUM TENSILE STRENGTH | 1500 POUNDS PER SQUARE INCH |
FLEX | FLEXIBILITY | FLEXIBLE |
HUES | COLOR | BLACK |
MATT | MATERIAL | RUBBER CHLOROPRENE CLASS CR |
STYL | STYLE DESIGNATOR | TRANSITION-1 TO 3 CABLES |